Model 2000 Gallus Diaphragm Gas Meter
OPERATING PRINCIPLE & USE
The Gallus 2000 uses the positive displacement diaphragm principle. Its design consists of a twin-chamber diaphragm-measuring unit. The twin chambers are each fitted with a flexible and gas-tight diaphragm, which move by the differential inlet and outlet pressure. A transmission system with a rotating mono-valve, and a valve system, transfer the reciprocating motion, driving the mechanical retrofittable index. The whole measuring system is contained in a robust gas-tight casing. The construction and the operation design of this meter make the Gallus 2000 an extremely reliable and accurate product.
The Gallus 2000 is made to measure accurately the volumes of natural gas (and LPG) used for domestic appliances. Please consult us for any other type of gas.
The Gallus 2000 is made to measure accurately the volumes of natural gas to 211 ft3/h (and LPG) used for domestic appliances. Please consult us for any other type of gas.
Typical Regulation Curve

- Over 15 millions
- installed worldwide
- Compact size
- Broad Metrological Performance: G 1.6 - G 2.5 - G 4
- High Accuracy and Long Term Reliability
- Not Susceptible to
Contamination (Glycol
Dust Test)
- Low Noise Level
- Fire Resistant Construction
- EEC Approval and More than 25 National Approvals
- Version Ready for Remote
Reading
- Versions for Budget Metering
- Utility Logo and Customized Bar Code by Laser Marking
- Index in Cubic Feet
- Connection with Pressure Test Nipple
- Large Range of Inlet and Outlet Connections (ISO, DIN, BSP, ASA... etc.)
- Radio Communication Module
- Prepayment Version
 |
|
| Size |
Natural Gas
d = 0.6 |
Air |
Propane |
Butane |
|
|
|
|
|
| G 1.6 |
0.4 mbar |
0.55 mbar |
0.7 mbar |
0.85 mbar |
|
| G 2.5 |
0.6 mbar |
0.8 mbar |
1.3 mbar |
1.6 mbar |
|
| G 4 |
1 mbar |
1.5 mbar |
2.5 mbar |
3.2 mbar |
|
|
- Retrofittable Pulse Transmitter
- Meter Bars for Two-pipe Meters
- Valves, Pipe Connections, Installation Cabinets
- Domestic Governors and Safety Cut-off Valves
- Maps Radio Frequency and Telephone Meter Reading System
- Measuring Range (G 4, G 2.5, G 1.6)
- Case Material and Working Pressure
- Connection Spacing and Size
- Specific Markings (logo, bar code, others)
Model 2000 Gallus Diaphragm Gas Meter
with an Aluminum Body |
Model 400g Gallus Diaphragm Gas Meter |
|
|
|
| Meter Case Material |
A |
B |
C |
D |
E |
Weight |
Connection Threads
According to ISO 228
(Consult us for any other connection) |
|
| Steel |
4.30" |
8.9" |
2.6" |
7.4" |
6.5" |
3.2 lbs |
3/4" NPT |
|

Please Contact Us for Other Requests
|
Use |
Natural gas and LPG (please consult us for any other type of gas) |
|
Cyclic Volume |
0.42 ft3 |
|
Operating Temperature |
-4°F to +104°C * |
|
Storage Temperature |
-40°C to +140°C * |
|
Maximum Operating Pressure |
7.25 psi for standard steel case meter |
|
Measuring Range |
G 1.6 Qmin 0.57 ft3/h Qmax 88 ft3/h
G 2.5 Qmin 0.88 ft3/h Qmax 141 ft3/h
G 4 Qmin 1.4 ft3/h Qmax 211 ft3/h |
|
Operational Pulse Generator |
Standard 1 ft3/ pulse |
|
Pulse Transmitter |
Retrofittable LF-system, 12V DC max
10mA max, standard 1 ft3/pulse
Wire fixation by jack plug or connecting block |
|
* PLEASE CONTACT US FOR TEMPERATURES OUTSIDE OF THIS RANGE
Download PDF Version • Download Installation Manual